Menu
Your Cart

GR1000T 10 Foot - Tenths LASERLINE Direct Reading Rod ( Lenker Style )

GR1000T 10 Foot - Tenths LASERLINE Direct Reading Rod ( Lenker Style )
GR1000T 10 Foot - Tenths LASERLINE Direct Reading Rod ( Lenker Style )
GR1000T 10 Foot - Tenths LASERLINE Direct Reading Rod ( Lenker Style )
GR1000T 10 Foot - Tenths LASERLINE Direct Reading Rod ( Lenker Style )
GR1000T 10 Foot - Tenths LASERLINE Direct Reading Rod ( Lenker Style )

LaserLine GR10T 10' Lenker Style Direct Reading Rod Ft/10ths

The GR10T 10' Lenker Style direct reading level rod, gradations in feet/tenths, allows you directly observe the true elevation of any point on the job site without any performing any calculations.

For use with optical levels (for use with a laser and detector, use a direct reading laser rod such as the GR1000 or GR1000T which have a track allowing you to slide the detector up and down).

Simply set the reading on the rod to match the elevation of a known elevation such as a benchmark or hub. This is possible because the rod face is actually a continuous flexible tape mounted on rollers within the frame of the rod which can be locked down once set. From then on, every elevation reading around the job site can be read directly through your optical level.

FEATURES:

The Laser Line GR10T Direct Reading grade rod is made of high strength clear anodized aluminum for lightweight rugged, dependable operation. It will not rust, split, splinter swell or warp in any environment.

The tape has a heavy duty matte textured face which is easy on the eyes in bright sunlight and protects the tape numbers from wear and fading.

Tape lock grommets are over sized,
heavy duty brass. This greatly minimizes the problem of tape tearing.

Detector rail is black, high density, U.V.stabilized for long life. It is specifically designed to not become brittle when exposed to ultraviolet rays or direct sunlight.

The solid tape lock has an internal brake slide for stronger, trouble-free operation.

Products Sold: 0
Product Views: 370
$395.00

DIRECTIONS FOR USING THE GR10T DIRECT READING ROD:

1. Set rod foot on a benchmark or hub with a known elevation; i.e. 2,525.25 elevation.

2. Using an optical instrument, (sight level, auto level, etc.) sight to the rod and use the horizontal line as your grade reference.

3. Loosen the tape lock pin (lower knob) and disengage the tape pin from the grommet.

4. Roll the tape face until 5.25 is the horizontal line on your optical instrument. You are using the last whole number and the decimal numbers of 2,525.25.

5. Lock the tape by engaging the tape lock pin into the nearest grommet. Then tighten the knob. You have now locked into the rod elevation (2,525.25). All future readings will be true elevation above or below 2,525.25 (5.25).

6. To find an elevation, simply set the rod foot at any location on the job within the range of your optical instrument. Using your optical instrument, just read the number across the horizontal line. That number is your true elevation.

EXAMPLE:
Rod reading is 6.10 = 2,526.10 true elevation
Rod reading is 8.32 = 2,528.32 true elevation
Rod reading is 4.70 = 2,524.70 true elevation